Recent Posts

Without the Right Adapters a Force Calibration Technician is Nothing Short of Being Called a Miracle Worker

Without the Right Adapters, a Force Calibration Technician is Nothing Short of Being Called a Miracle Worker Figure 1 Bent Rod End Think about that for a minute. Would you want a surgeon to operate on you with kitchen utensils such as a serrated knife? Then why do some people (management cough) expect or ask […]

ASTM E74 is Not the Same as ISO 376

ASTM E74 is Not the Same as ISO 376 Morehouse has been performing both ASTM E74 and ISO 376 calibrations for more than fifteen years. We have been calibrating in accordance with the ASTM E74 standard since its introduction in 1974, and performing ISO 376 calibrations since sometime in early 2000. Prior to early 2000, […]

Morehouse ISO 376 Calibration Certificates

Morehouse ISO 376 Calibration Certificates Morehouse has been performing ISO 376 calibrations for over the last fifteen years. In this time frame, we have changed our ISO 376 calibration certificate format three times. The latest change offers additional information such as a calibration graph per run and is laid out in a way that is […]

Calibrating Multi-Axis Load cells in a Morehouse Calibrating Machine

Multi-axis load cell Multi-Axis load cells are becoming more popular, and the calibration of such load cells creates various challenges to ensure minimal cross-talk and to calibrate each axis of the load cells. This blog describes a detailed test plan for calibrating a 3-axis multi-axis load cell in a Morehouse. Universal Calibrating Machine (pictured below). […]

Morehouse Force Calibration Adapters for Calibration of Lifting Devices such as Crane Scales, Tension Links, and Dynamometers.

Morehouse Force Calibration Adapters for Calibration of Lifting Devices such as Crane Scales, Tension Links, and Dynamometers Figure 1 Morehouse Tension Force Calibration Adapters Quick Change Tension Member System I am about to tell you a little bit about our calibration adapter history and what we have been working on to simplify your life when […]

Choosing the Right Load Cell Indicator

Choosing the Right Load Cell Indicator Does the indicator have to be better than 0.005 %? Are you willing to use a computer to convert mV/V to Engineering Units? Do you require portability without a power adapter? Do you have more than two load cells? HADI Do you require portability without a power adapter? Do […]

Guidance on Uncertainty Budgets for Force Measuring Devices Part 3. Calculating Uncertainty for Force Measuring Devices for Measurement or Verification of Force Using Non-Linearity

Guidance on Uncertainty Budgets for Force Measuring Devices Part 3. Calculating Uncertainty for Force Measuring Devices for Measurement or Calculating Uncertainty for Force Measuring Devices Background: Currently, there are discrepancies regarding what is acceptable for a force calibration uncertainty budget.  A common mistake is to include too many lines from the load cell specification sheet. For […]

Guidance on Uncertainty Budgets for Force Measuring Devices Part 2. Calculating Uncertainty in Accordance with ASTM E74 Standard

Guidance on Uncertainty Budgets for Force Measuring Devices Part 2. Calculating Uncertainty in Accordance with ASTM E74 Standard Calculating Uncertainty in accordance with ASTM E74 Standard Background: ASTM E74 Standard Practice of Calibration of Force-Measuring Instruments for Verifying the Force Indication of Testing Machines is the standard followed by many in North America for the […]

Guidance on Uncertainty Budgets for Force Measuring Devices Part 1. Why Do We Need a Solid Guidance Document?

Guidance on Uncertainty Budgets for Force Measuring Devices Part 1. Why Do We Need a Solid Guidance Document? Uncertainty Budgets for Force Measuring Devices Introduction: All calibration laboratories accredited to ISO/IEC 17025 must submit uncertainty calculations for the Calibration and Measurement Capability uncertainty claims included in the scope of accreditation. The assumptions made to determine the uncertainty […]
1 18 19 20 21 22 27

When You're Looking for More Accurate Measurements

Morehouse would like the opportunity to earn your business. Contact us today.
Contact Us
  • Type

Top cross linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram