• Type

4215-HS Load Cell Indicator Manual: This manual explains the setup and operation of the Morehouse 4215HS. Click here to download the manual. If you enjoyed this content, check out our LinkedIn and YouTube channel for more helpful posts and videos.  
Automatic Deadweight Load Cell Calibration Instrument for Improved Force Calibration Results Figure 1: Morehouse 1,000 lbf Automatic Deadweight Load Cell Calibration Machine Deadweight Load Cell Calibration Machine used to calibrate load cells may vary from ones with the lowest overall uncertainty such as deadweight force standard machines sometimes called primary standards to single or multiple transducer […]
4215 Plus Load Cell Indicator Manual: Use the coefficients to convert mV/V into lbf, kgf, N, and eliminate span calibration errors when you use the calibration equation of several ASTM E74 & ISO 376 calibration reports. More information on our 4215 plus can be found here. If you enjoyed this content, check out our LinkedIn […]
Big News: Morehouse Training, Sessions, and Presentations at NCSLI 2018 in Portland August 26 - 30 Another year and another NCSLI conference are soon approaching. This year both Henry Zumbrun and Edward Lane will be headed out to NCSLI. I will be teaching two tutorials on Monday, August 20th, presenting some torque wrench PT findings […]
4215 Plus Polynomial Instructions: Quick set of instructions for use to enter polynomial coefficients into the Morehouse 4215 plus indicator. More information on all of our meters can be found here. If you enjoyed this content, check out our LinkedIn and YouTube channel for more helpful posts and videos.
Load Cell Stability – How It Can Kill Your Uncertainty Budget Load cells are a combination of metal, strain gauges, adhesive, and more.  Like humans, every measuring instrument is subject to aging.  Load cells age from mechanical stress or fatigue, and over time this ensures that there will be some instability in the system. Some […]
Cosine Error Should be Considered in any Torque Measurement Process ISO/IEC 17025 When Calculating Torque Measurement Error Cosine Error should be considered A ‘vector’ is known as a quantity that is defined by its size and direction. Every time the effect of a known force is evaluated on a static or dynamic system, all applied, […]
GB2 High Stability Gauge Buster Indicator Manual: Below, the manual is attached. For more information on load cell meters that Morehouse offers, click here. If you enjoyed this content, check out our LinkedIn and YouTube channel for more helpful posts and videos.
Using Mass Weights to Calibrate Force Devices Can Result in a Large Measurement Error Morehouse Benchtop 10,000 lbf Calibrating Machine When metrologists talk about measurement error, we’re talking about the difference between the nominal value and what the instrument is reading. If 10,000 lbf is applied to a force measuring device and the readout displays […]