Looking for an affordable and highly accurate indicator with a display?
The model 4215 high stability load cell indicator is often the choice for calibration labs that do not want to spend ten times more money for their load cell instrumentation. It is 6-wire sensing, highly accurate benchtop indicator with a display.
This popular high stability load cell indicator is in stock now!
The Morehouse 4215 High Stability Load Cell Indicator uses strain gauge-based load cells. It is a robust, portable load cell indicator with sense. The six-wire sensing eliminates errors from resistance changes due to temperature, as well as the length and gauge of the cable.
This indicator can read mV/V and use free, custom Morehouse software to convert the mV/V units to engineering units with coefficient files from ASTM E74 or ISO 376 reports. This meter is often the choice for accredited calibration service providers who want high accuracy and convenience but do not want to break the bank.
Features include:
Morehouse has computer software available for the 4215-HS that allows for conversion from mV/V to lbf, kgf, kN, N and reduces the overall cost for the customer while meeting the quality requirements in ISO/IEC 17025:2017 and complying with ASTM E74 and ISO 376 standards.
NCSLI RP-12 states in section 12.3 “The uncertainty in the value or bias, always increases with time since calibration”. When the drift occurs, the indicator needs to be reprogrammed. Most quality systems require an "As Received" calibration. Therefore, the indicator needs to be reprogrammed, and an "As Returned" calibration is performed.
The actual level of work results in calibration costs that are much higher than they need to be. Morehouse has developed software to avoid the excess costs because the coefficients used in the software are based on mV/V values and the "As Received" and "As Returned" calibrations are the same. The end-user only needs to update the coefficients in the computer software.
A video comparing a 4215 High Stability Load Cell Indicator against a normal 4215 Load Cell Indicator can be found here.
Morehouse Free Calibration Software: Download Today
Morehouse calibration software allows readings from any number of Morehouse indicators that have a communication output (USB or serial). If multiple indicators are used, their values can be added together to show a total value. The software can do the unit conversion (between force units and mass units), and mass conversion, and adjust the resolution at the values shown, and much more!
Note: If a computer is not allowed in the working area and direct reading from the indicator is needed, select a 4215+ indicator. Coefficient files are loaded into the indicator for direct reading, from the calibration curve.