Morehouse Verification Sheet for Legacy Software: This is a one-sheet verification for the Morehouse Calibrator legacy software. The verification verifies the software converts the mV/V values properly. The end-user must still verify they have entered the coefficients correctly. The sheet provides the verification documentation necessary for audits. If you enjoyed this content, check out our […]
Guidance on Uncertainty Budgets for Force Measuring Devices Part 2. Calculating Uncertainty in Accordance with ASTM E74 Standard Calculating Uncertainty in accordance with ASTM E74 Standard Background: ASTM E74 Standard Practice of Calibration of Force-Measuring Instruments for Verifying the Force Indication of Testing Machines is the standard followed by many in North America for the […]
Morehouse Calibration Software New Release Page (click to visit) Instruction Manual (click to download) Morehouse calibration software allows readings from any number of Morehouse indicators that have a communication output (USB or serial). If multiple indicators are used, their values can be added together to show a total value. The software displays values by converting the […]
Guidance on Uncertainty Budgets for Force Measuring Devices Part 1. Why Do We Need a Solid Guidance Document? Uncertainty Budgets for Force Measuring Devices Introduction: All calibration laboratories accredited to ISO/IEC 17025 must submit uncertainty calculations for the Calibration and Measurement Capability uncertainty claims included in the scope of accreditation. The assumptions made to determine the uncertainty […]
Morehouse force software verification Excel sheet. The Excel sheet verifies the force software from Morehouse. The sheet includes formulas and screenshots to prove the Morehouse force calibration does what it should. Download our force verification sheet for force verification. If you enjoyed this content, check out our LinkedIn and YouTube channel for more helpful posts […]
What Happens When You Overshoot a Test Point? Various calibration laboratories use hydraulic, screw, and other force calibration machines where it is difficult not to overshoot a test point.  By talking about overshooting a test point, we are referring to loading past the desired point and then letting the creep in the hydraulic system naturally […]
Software for reading two indicators at the same time V1.3.5: Force calibration software for use with Morehouse 4215, HADI, or DSC-USB Indicators. Read two indicators at the same time. The software uses coefficients from ASTM E74 calibration and displays engineering units as well as capturing data with a remote control device and pausing readings etc.., Reporting […]
The Top 5 Costly Force Measurement Mistakes #1 of 5 Costly force measurement mistakes Most calibration laboratories will say a device is "In Tolerance" without considering the uncertainty of their measurement process. This equates to you not using a calibration laboratory that has standards to meet your needs and accounts for measurement risk properly. Most […]
Morehouse Torque Installer Software V1.2: The torque installer software is the universal version for torque calibration which allows for lbf ft and N m coefficients to be entered.  PEAK HOLD and new windows 8/10 drivers on this version. Inverse B0 coefficients. If you enjoyed this content, check out our LinkedIn and YouTube channel for more […]