Recent Posts

Morehouse Force Training Courses

Morehouse offers force training courses and torque training, both virtual and in-person. Our training courses are multiple days and teach the participant the fundamentals of force calibration. The force training course is excellent for all skill levels as we cover what matters most and what many people get wrong (measurement errors, troubleshooting, adapters, uncertainty, technique).  […]

How Low Can My Load Cell Go?

So, how low can my load cell go? Like the Limbo, everything has a point where going lower is impossible. In this article,  "How Low Can My Load Cell Go?" Morehouse Instrument Company President Henry Zumbrun provides three things to consider regarding measurement uncertainty when you ask how low your load cell can go.  The […]

Let's Talk About Measurement Bias

Measurement Bias: What can happen when we use an accuracy specification and assume all the measurements are centered to the specification limits? Not correcting for Measurement Bias is a typical problem in the metrology community, where many papers assume a centered process or Measurement and that any known Measurement Bias has been corrected. The Morehouse […]

An Introduction to the Differences Between ASTM E74 and ISO 376 the Two Most Recognized Force Standards

An Introduction to the Differences Between ASTM E74 and ISO 376, the Two Most Recognized Force Standards: The differences Between ASTM E74 and ISO 376 can be confusing. Morehouse has been performing both ASTM E74 and ISO 376 calibrations for more than fifteen years. We have been calibrating in accordance with the ASTM E74 standard […]

Capability Statement for Morehouse Cage Code 90562

Capability Statement for Morehouse Instrument Company. Cage code 90562. Simple One-Page Statement for Morehouse. Morehouse Instrument Company’s in-house manufacturing facility can build equipment to your specifications. Our ISO/IEC 17025, ANSI/NCSLI Z540.1 & .3 accredited calibration services use primary standards to obtain the lowest uncertainties (10-50 times lower than most service providers) possible. If you enjoyed […]

Download the paper the new dimension to resolution

The new dimension to resolution paper. This paper stresses the importance of considering the unit under test resolution in a measurement uncertainty budget. Download our new dimension to resolution paper here. If you enjoyed this content, check out our LinkedIn and YouTube channels for more helpful posts and videos.

The top 4 Common Measurement Errors in Weighing

A paper on the Common Measurement Errors in Weighing. Anyone calibrating or using crane scales, load cells, dynamometers, truck scales, and aircraft scales will benefit from learning about the various common errors in weighing. Download our Common Errors in Weighing paper here. If you enjoyed this content, check out our LinkedIn and YouTube channel for […]

Analyzing the Effects of Reducing the Ending Zero vs Ignoring the Trailing Zero on Measurement Instruments Used for Force Calibration (2014)

Analyzing the Effects of Reducing the Ending Zero vs Ignoring the Trailing Zero on Measurement Instruments Used for Force Calibration (2014): ASTM E74 Method A and Method B—for the treatment of reducing the ending zero. Method A defines the deflection calculation as the difference between the deflection at an applied force and the initial reading […]

Potential Measurement Errors in Force Calibration

Potential Measurement Errors in Force Calibration: This article covers the most common errors one must know when making calibrating force instrumentation. Potential Measurement Errors in Force Calibration in published test magazine from Oct-Nov 2015 issue. If you enjoyed this content, check out our LinkedIn and YouTube channel for more helpful posts and videos.

What is Measurement Risk?

What is measurement risk? Measurement decision risk is the probability that an incorrect decision will result from a measurement. Are you telling your customers instrument passes without considering measurement uncertainty? If taken to court, are your measurement defensible? This paper examines the proper way to make statements of compliance. Download our Measurement Risk paper here. […]

Load Cell Dual-range Calibration - Force Potential Measurement Error (2016)

Load cell dual-range calibration errors happen when a load cell is not loaded to full capacity. The molecules inside the load cell do not react potentially causing an increased error. What you need to know about molecule excitement decline and dual-range calibrations. Article from Test Magazine May 2016 issue. If you enjoyed this content, check […]

Why a 4 to 1 TUR is Not Enough: The Importance of Analyzing the Probability of False Accept Risk

Why a 4 to 1 TUR is Not Enough: The Importance of Analyzing the Probability of False Accept Risk: Several organizations and publications reference or insist on maintaining a 4 to 1 TUR (Test Uncertainty Ratio) without understanding the level of risk that they may be subjecting themselves to. The general thought is that if […]

When You're Looking for More Accurate Measurements

Morehouse would like the opportunity to earn your business. Contact us today.
Contact Us
  • Type